Skip to content

Cryotherapy for sports clubs and gyms

Recovery in three minutes per athlete. For clubs, academies and premium gyms.

Request a quote
Cryotherapy chamber in a gym

Boxing & combat sports

Recovery beside the ring.

For boxing gyms, combat-sports studios and performance centres.

Cryotherapy chamber in a boxing gym
eCham now cryotherapy chamber

REF. PQ-3100

eCham now

High throughput on a standard socket

Sessions per day
45
Standard socket
230 V

Cooling technology: Wind Chill. Draws up to 2 kW, weighs ~400 kg, measures 1,400 × 1,200 × 2,270 mm (W × D × H). Three temperature levels: −70, −90 and down to −110 °C.

Ideal for: Gyms, Physiotherapy practices

Details for eCham now
eCham max cryotherapy chamber

REF. PQ-6100

eCham max

Top of the range

Sessions per day
100+
Three-phase supply
400 V

Cooling technology: Evaporator. Draws up to 7 kW, weighs ~600 kg, measures 1,944 × 1,376 × 2,425 mm (W × D × H). Three temperature levels: −70, −90 and down to −110 °C.

Ideal for: Large resorts, Professional teams

Details for eCham max
eCham pure cryotherapy chamber

REF. PQ-4100

eCham pure

Clinic-grade

Sessions per day
70
Three-phase supply
400 V

Cooling technology: Evaporator. Draws up to 3.5 kW, weighs ~520 kg, measures 1,944 × 1,376 × 2,425 mm (W × D × H). Three temperature levels: −70, −90 and down to −110 °C.

Ideal for: Performance studios, Rehabilitation centres

Details for eCham pure
eCham flow cryotherapy chamber

REF. PQ-5100

eCham flow

High performance

Sessions per day
100
Three-phase supply
400 V

Cooling technology: Wind Chill. Draws up to 3.5 kW, weighs ~550 kg, measures 1,850 × 1,200 × 2,370 mm (W × D × H). Three temperature levels: −70, −90 and down to −110 °C.

Ideal for: Resorts and spas, Sports clubs

Details for eCham flow

Frequently asked questions

How long is a session?

Three minutes, with three selectable temperature levels: −70, −90 and down to −110 °C.

Do we need specialist staff?

No. Trained staff run it alongside their regular work: they accompany the entry, start the session and stay nearby with visual contact. Handover includes hands-on training in operation, safety and cleaning.

Does it need a special power supply?

The eCham home, smart and now run on a standard 230 V / 16 A socket. The pure, flow and max need a three-phase 400 V supply.

What maintenance does it need?

Daily cleaning and a visual check, plus regular technical maintenance to the manufacturer's schedule, matched to your throughput. Maintenance intervals are agreed in writing before handover. The manufacturer ProseQ gives a 2-year warranty on the hardware.

Request a quote